• +976-70008383
  • info@energytech.mn
Choice language :
AS

АS per GOST 839-80
Non-insulated wire, consist of steel central core and Al wires

CONSTRUCTION
Wires consist of steel central core and Al wires, stranded by right stranding with stranding direction of neighbor lays toopposing sides, outer lay have stranding direction right.


OKP CODES:
35 1141 01 — for AS wires


APPLICATION
Non-insulated wires type Аs are apply for transmission of electric power in aerial electric networks, in air atmosphere types I and II having sulfurous gas no more than 150g/m2 per day (1,5mg/m3) on land for all climatic regions per GOST 15150 type “UHL”, except “ТВ” and “ТС”.

TECHNICAL SPECIFICATION
Permissible longitudal temperature of wires at operation not more than..............+900С

Number of wires in the wire, their nominal diameter, the number of helix and the structural length of wires makes the AU are presented in the table below:

Rated.area, mm2
Aluminum wire of
Steel core
The number of helix
The ratio of cross Alum. pieces of wire to the cross section of steel core
Building length of wires, meters, at least   
Number of wires
Nominal wire diameter, mm
Number of wires
Nominal wire diameter, mm
Aluminum.Wires
Steel wires
16/2,7
6
1,85
1
1,85
1
-
6,00
3000
25/4,2
6
2,30
1
2,30
1
-
6,00
3000
35/6,2
6
2,80
1
2,80
1
-
6,00
3000
40/6,7
6
2,91
1
2,91
1
-
6,00
3000
50/8,0
6
3,20
1
3,20
1
-
6,00
3000
63/10,5
6
3,66
1
3,66
1
-
6,00
2000
70/11
6
3,80
1
3,80
1
-
6,00
2000
95/16
6
4,50
1
4,50
1
-
6,00
1500
100/16,7
6
4,61
1
4,61
1
-
6,00
1500
120/19
26
2,40
7
1,85
2
1
6,25
2000
120/27
30
2,20
7
2,20
2
1
4,29
2000
125/6,9
18
2,97
1
2,97
2
-
18,11
2000
125/20,4
26
2,47
7
1,92
2
1
-
2000
150/19
24
2,80
7
1,85
2
1
7,85
2000
150/24
26
2,70
7
2,10
2
1
6,14
2000
150/34
30
2,50
7
2,50
2
1
4,29
2000
160/8,9
18
3,36
1
3,36
2
-
-
2000
160/26,1
26
2,80
7
2,18
2
1
-
2000
185/24
24
3,15
7
2,10
2
1
7,71
2000
185/29
26
2,98
7
2,30
2
1
6,24
2000
185/43
30
2,80
7
2,80
2
1
4,29
2000
200/11,1
18
3,76
1
3,76
2
-
-
2000
200/32,6
26
3,13
7
2,43
2
1
-
2000
205/27,0
24
3,30
7
2,20
2
1
7,71
2000
240/32
24
3,60
7
2,40
2
1
7,71
2000
240/39
26
3,40
7
2,65
2
1
6,11
2000
300/39
24
4,00
7
2,65
2
1
7,81
2000
300/48
26
3,80
7
2,95
3
1
6,16
2000
315/21,8
45
2,99
7
1,99
2
1
-
2000
315/51,3
26
3,93
7
3,05
3
1
-
2000
330/30,0
48
2,98
7
2,30
3
1
11,55
2000
330/43,0
54
2,80
7
2,80
3
1
7,71
1500
400/18
42
3,40
7
1,85
3
1
20,27
1500
400/27,7
45
3,36
7
2,24
3
1
-
1500
400/51
54
3,05
7
3,05
3
1
7,71
1500
400/51,9
54
3,07
7
3,07
3
1
-
1500
450/31,1
45
3,57
7
2,38
3
1
-
1500
500/26
42
3,90
7
2,20
3
1
18,86
1200
500/34,6
45
3,76
7
2,51
3
1
-
1000
560/38,7
45
3,98
7
2,65
3
1
-
1000
630/43,6
45
4,22
7
2,81
3
1
-
1000
710/49,1
45
4,48
7
2,99
3
1
-
1000

 

 

Calculated structural and technical parameters of wires mark the AU are presented in the table below:

 

Nominal section (aluminum / steel, mm2)
 
 
Diameter, mm
Electr. Pair. 1 km of wire position. current at 20 ° C, 0 m, max
Breaking strength, N is not less
Aluminum parts
Weight of 1 km of wire, kg
Wires
Steel core
 
 
 
 
 
 
Steel core
Wires
16/2,69
5,6
1,9
1,7818
6220
44,0
20,9
64,9
24,9/4,15
6,9
2,3
1,1521
9296
67,9
32,4
100,3
36,9/6,15
8,4
2,8
0,7774
13524
100,0
48,0
148,0
40/6,7
8,74
2,91
0,7172
14400
-
-
161,3
48,2/8,04
9,6
3,2
0,5951
17112
132,0
63,0
195,0
63/10,5
10,97
3,66
0,4553
21630
-
-
254,0
68/11,3
11,4
3,8
0,4218
24130
188,0
88,0
276,0
95,4/15,9
13,5
4,5
0,3007
33369
261,0
124,0
385,0
100/16,7
13,82
4,61
0,2868
34333
-
-
403,2
118/18,8
15,2
5,6
0,2440
41521
324,0
147,0
471,0
114/26,6
15,4
6,6
0,2531
49465
320,0
208,0
528,0
125/6,9
14,67
2,97
0,2304
29167
-
-
397,9
125/20,4
15,67
5,77
0,2308
45694
-
-
503,5
148/18,8
16,8
5,6
0,2046
46307
407,0
147,0
554,0
149/24,2
17,1
6,3
0,2039
52279
409,0
190,0
599,0
147/34,3
17,5
7,5
0,2061
62643
406,0
269,0
675,0
160/8,9
16,82
3,36
0,1800
36178
-
-
509,4
160/26,1
17,73
6,53
0,1803
57689
-
-
644,5
187/24,2
18,9
6,3
0,1540
58075