APV, PV1

CONSTRUCTION

  1. CONDUCTING CORE:
    — in APV wires: Al, single- or multiwire core, class 1 for cross-section from 2,5 up to 16 mm2 incl., class 2 for cross-section from 25 up to 120 mm2 incl. per GOST 22483;
    — In PV-1 wires: Cu, single- or multiwire core, class 1 for cross-section from 0,5 up to 10 mm2 incl., class 2 for cross-section from 16 up to 95 mm2 incl. per GOST 22483. 
  2. INSULATION — from PVC compound various coloring. Coloring is continuous or of 2
    longitudinal stripes put diametrically on insulation of natural color. The wires, used as grounding core have green-yellow coloring. The color of solid insulation or stripes should be bespeaced at ordering and have identification mark.

APPLICATION
Wires are apply for electric facilities at stationary cabling in lighting and power networks, and also for installation of electric equipment, machines and devices on nominal AC voltage up to 450 V (from networks up to 450/750 V) of frequency up to 400 Hz or DC voltage up to 1 kV. APV and PV-1 wires are apply for cabling in steel tubes, cavitated channels of building structures, on cable trays and others, for assembling of electric circuits.


OKP CODES:
35 5133 01 — for APV wires
35 5113 01 — for PV-1 wires


TECHNICAL SPECIFICATION
Climatizaton type “HL”, allocation category 2 per GOSTТ 15150-69.
Wires are resistant to action of environment temperature...................................from -500С up to +700С
Wires are resistant to action ofair relative humidity 100% at temperature +350С
Wires are resistant to action of mold fungi.
Wires are resistant to action of mechanical shocks, linear acceleration, bendings, vibration strains, audio noises.
Wires are not spread the burning.
Installation of wire at temperature not lower than ...........................................-150С
Bending radius at cabling, not less .................................................................10 diameters of the wire 
Permissible cpntinuous heating of the cores, not more than ..............................+700С
Construction lengh, not less than ..................................................................100 m

 

 

APV
The number of cores and,
mm2
Outside diameter
cable
Weight of 1 km of cable,
kg
1х2,5
3,26
14
1х4
3,72
20
1х6
4,22
26
1х10ozh
5,40
43
1х10
5,95
47
1х16ozh
6,35
63
1х16
6,80
66
1х25
8,10
100
1х25ozh
7,80
97
1х35
9,10
130
1х35ozh
8,80
127
1х50
10,80
190
1х50ozh
10,50
 
182
1х70
12,20
246
1х95
14,30
325
1х120
15,70
400
1х150
17,30
502
1х185
19,30
609
1х240
22,00
791

 

 

PV-1
The number of cores and,
mm2
Outside diameter
cable
Weight of 1 km of cable,
kg
1х0,5
1,89
7
1х0,75
20,70
10
1х1
2,23
13
1х1,5
2,66
18
1х2,5
3,26
29
1х4
3,72
44
1х6
4,22
62
1х10ozh
5,40
103
1х10
5,95
109
1х16ozh
6,35
159
1х16
6,80
164
1х25
8,10
253
1х25ozh
7,80
249
1х35
9,10
337
1х35ozh
8,80
339
1х50
10,80
503
1х50ozh
10,50
485
1х70
12,20
672
1х95
14,30
874
1х120
15,70
1095
1х150
17,30
1395
1х185
19,30
1677
1х240
22,00
2190