• +976-70008383
  • info@energytech.mn
Choice language :
AVBbSHv

AVBbSHv for 0.66 kV. 1.0 kV to GOST 16442-80
Power aluminum cables. PVC insulation and cable armoring of BbSHv type
AVBbSHv for 0.66 kV. 1.0 kV to TU 3500-002-59680332-2004
Power aluminum cables. PVC insulation and cable armoring of BbSHv type . characterized by low inflammability

CONSTRUCTION

  1. CONDUCTING CORE – aluminum, single-core or multicore, round- or sector-shaped. first or second class per GOST 22483
  2. INSULATION – made of polyvinilychloride compound (PVC). Insulated cores of multicore cables have distinctive colouring. Zero core’s insulation is coloured blue. Grounding core’s insulation is coloured dichromatically (green-yellow).
  3. STRANDING – insulated cores of two-, three-, four-, and five-core cable are stranded; twocore cables have cores of identical cross-section;three-, four-, five-core cables have all cores of identical cross-section or one core of a smaller cross-section (zero core or grounding core).
  4. WRAPPING – in cables with cable armoring of BbSHv type pressed off from PVC compound or insulation material or other equivalent material; in AVBbSHng cables it is laid between the cores with the gaps filled by PVC compound, characterized by low inflammability.
  5. CABLE ARMORING – of BbSHv type is shown by:
    -armouring made of two steel galvanized strips laid one over another in the way that the upper strip spans the gaps between wraps of the lower one;
    - sheath pressed off from PVC compound.
    -from PVC compound characterized by low inflammability in AVBbSHngcables.

APPLICATION:
For transmission and distribution of power in permanent facilities intended for rated AC voltage of 0.66 kV and 1.0 kV at the frequency of 50 Hz. Single-core cables are used in direct-current voltage
For laying in the ground (trenches), premises ( buildings), canals, tunnels, mines (except for blocks), as well as outdoors, on condition that no sizeable stretching force is applied to the cable. but with the presence of mechanical damage risk in operation.
AVBbSHv cables do not spread burning at single cabling.
AVBbSHng cables do not spread burning at cabling in bunches.


OKP CODES:
35 2222 41 — AVBbSHv cables rated for 0.66 kV
35 3771 57 — AVBbSHv cables rated for 1.0 kV
35 3771 09 — AVBbSHng cables rated for 1.0 kV


TECHNICAL DETAILS
Type of climatization is UHL and Т, allocation category - 1 and 5 as per GOST 15150-69
Working temperatures range.............................................................................from -50°С to +50°С
Relative air humidity at temperatures lower than +35°С ........................................up to 98%
Temperature for installation and mounting without preheating, not below..............- 15°С
Minimum bending radius at cabling:
single-core AVBbSHv cables ............................................................................. 10 outer diameters
single-core AVBbSHng cables ............................................................................15 outer diameters
multicore .......................................................................................................7.5 outer diameters
Frequency rating.............................................................................................50 Hz
Test rated AC voltage of 50 Hz frequency rating:
for 0.66 kV voltage..........................................................................................3 kV
for 1.0 kV voltage............................................................................................3.5 kV
Permissible continuous operative temperature of cable core’s preheating ................+70°С
Cable construction length with the main core’s cross-sections:
from 1.5 to 16mm2..........................................................................................450 m
from 25 to 70 mm2..........................................................................................300 m
from 95 mm2 and more.....................................................................................200 m

AVBbSHv cables with round-core

 

Number and nominal cross-section of the cores, mm2

Outer diameter of the cable, mm

Weight of cable 1 km/kg

0.66 KV

1 KV

0.66 KV

1 KV

2х2.5
13.6
13.6
275
272
2х4
14.4
15.2
302
328
2х6
15.4
16.2
340
368
2х10 single core
17.4
17.8
419
425
2х16 single core
19.3
19.7
495
510
2х16
20.2
20.6
522
538
2х25 single core
22.6
23
469
665
2х25
23.2
23.6
688
685
2х35 single core
25
25.4
780
798
2х35
25.6
26
799
817
2х50 single core
28.4
28.8
974
993
2х50
29
29.4
1002
1021
2х70
 
32.2
 
1206
2х120
 
39.2
 
1698
2х150
 
42.4
 
1984
2х185
 
46.4
 
2314
 
 
 
 
 
3х240
 
51.8
 
2818
3х2.5
13.6
14
280
294
3х4
15
15.8
335
366
3х6
16.1
16.9
382
414
3х10 single core
18.2
18.6
470
487
3х16 single core
20.2
20.6
577
595
3х16
21.2
21.6
608
627
3х25 single core
23.8
24.2
771
791
3х25
24.4
25.3
793
837
3х35 single core
26.3
26.8
937
959
3х35
27
27.4
959
982
3х50 single core
30
30.4
1192
1216
3х50
30.6
31.1
1227
1251
3х4+1х2.5
15.9
16.5
371
395
3х6+1х4
17.1
18.1
427
457
3х10+1х6
19.5
20
528
549
3х16+1х10 single core
21.8
22.3
656
677
3х16+1х10
22.2
22.7
674
696
3х25+1х16 single core
25.4
26.6
882
926
3х25+1х16
26.1
26.6
908
932
3х35+1х16 single core
27.7
28.2
1032
1057
3х35+1х16
27.7
28.1
1037
1062
3х50+1х25 single core
31.6
32.1
1328
1356
3х50+1х25
32.3
32.8
1364
1396
4х2.5
14.3
14.8
312
329
4х4
15.9
16.9
377
414
4х6
17.1
18.1
434
464
4х10 single core
19.5
20
542
562
4х16 single core
21.8
22.3
675
697
4х16
22.9
23.3
712
735
4х25 single core
26.2
12.1
221
235
4х25
26.9
27.4
965
991
4х35 single core
28.6
29
1118
1145
4х35
29.3
29.8
1144
1172
4х50 single core
32.7
33.9
1438
1511
4х50
33.4
33.9