PVS, PVSn

PVS per GOST 7399-97
Wire with stranded Cu cores, PVC insulation and PVC sheath, flexible, for voltage up to 380/660 V
PVSn
The same, but not apply for armouring by undismountable armature

CONSTRUCTION

  1. CONDUCTING CORE — Cu or tinned Cu (per request of customer at ordering may be add the marking "л" (tinned)), round shaped, multi-core of class 5 per GOST 22483.
  2. INSULATION — from PVC compound.
  3. STRANDING — insulated cores are stranded without filling. Insulated cores of five-core wires can be stranded around central core.
  4. SHEATH — from PVC compound. Sheath is put with filling between cores, providing roung form.
     

APPLICATION
Apply for connection of electric devices and electric tools for home-use, washing machine, refregirator, gardening machine and ect., for producing of extencion cords for voltage up to 380 V for systems 380/660 V.


OKP CODES:
35 5513 02 — for PVS, PVSn wires
35 5513 21 — for PVS-Т wires

TECHNICAL SPECIFICATION
Climatization type per GOST 15150:
“U” – allocation category 1, 2, 3
“T” – allocation category 4
“UHL” – allocation category 4
Wires of climatization type “U” apply for operation at environment temperature .............from -400С up to +400С
Wires of other climatization type .............................................................................from -250С up to +400С
Maximal temperature of conducting core at operation ................................................+700С
Wires after water storage at temperature (20±5)0С during 1 h.
Stand the testing by AC voltage 2000 V of frequency 50 Hz during..............................15 minutes
Wires are not spread the burning at single cabling.
Setted no-filure operating time not less than ............................................................5000 h
Setted no-filure operating time for wires, used in stationary electric devices, not less than........12000 h
Construction lengh not less than .............................................................................50 m
Warranty period ...................................................................................................2 years since putting into operatiod
Service life not less than ........................................................................................6 years
Service life, for wires, used in stationary electric devices, not less than .........................10 years

 

Numbercross-section, mm2
Nominal thickness, mm
External dimensions of conductor PVSn mm
External dimensions of conductor PVA, mm
Estimated weight of 1 kg of wire, kg
Insulation
Shell
Min.
Max.
Min.
Max.
2x0,75
0,6
0,8
5,7
7,2
6,0
6,6
52
2x1,0
0,6
0,8
5,9
7,5
6,4
7,0
59
2x1,5
0,7
0,8
6,8
8,6
7,4
8,2
81
2x2,5
0,8
1,0
8,4
10,6
-
-
123
3x0,75              
0,6
0,8
6,0
7,6
6,4
7,0
61
3x1,0
0,6
0,8
6,3
8,0
6,8
7,6
71
3x1,5
0,7
0,9
7,4
9,4
8,0
8,8
101
3x2,5
0,8
1,1
9,2
11,4
-
-
154
4x0,75
0,6
0,8
6,6
8,3
-
-
74
4x1,0
0,6
0,9
7,1
9,0
-
-
89
4x1,5
0,7
1,0
8,4
10,5
-
-
127
4x2,5           
0,8
1,1
10,1
12,5
-
-
188
5x0,75             
0,6
0,9
7,4
9,3
-
-
90
5x1,0
0,6
0,9
7,8
9,8
-
-
106
5x1,5
0,7
1,1
9,3
11,6
-
-
155
5x2,5
0,8
1,2
11,2
13,9
-
-
229